Prom – найбільший маркетплейс України

DATAKOM DKG-151 Manual start generator control panel

В наличии
5 146 

Доставка

  • Иконка доставки
    Нова Пошта

Оплата и гарантии

  • Иконка оплаты
    Наложенный платеж
    Нова Пошта
DATAKOM DKG-151 Manual start generator control panel - фото 1 - id-p2898685454

Характеристики и описание

Основные

Производитель
Datakom

Пользовательские характеристики

Вес0.178
ВидНоменклатурыТовар
Картинкиhttp://www.controllers4generators.com/upload/iblock/0c6/n36yobydyqwwbma6x6vuebt85iv6hic2/DATAKOM-DKG151.resize1.jpg
ТипНоменклатурыЗапас
ШтрихКод2601510122848
The DATAKOM model DKG-151 is a low cost, microprocessor controlled unit designed to start and stop the genset manually using the key switch and pushbuttons on the front panel. It has high power relay outputs enabling it to interface directly with diesel gensets. When the engine is running, the unit monitors fault conditions and shuts-down the engine automatically in the occurrence of an alarm. In the OFF position, the DC supply is removed from the module, thus zero power consumption is achieved. When the engine is running, the unit monitors fault conditions and shuts-down the engine automatically in the occurrence of an alarm. The alarms are identified by a group of LEDs displaying only the first occurring one. The occurrence of below fault conditions will cause the engine to be stopped immediately: overspeed, underspeed, high engine temperature, low of pressure, Auxiliary shutdown. The limits for the correct generator frequency are 25 to 57 Hz for 50Hz operation and, 25 to 68 Hz for 60Hz operation. The unit uses high current two part connectors for easy replacement. The DKG-151 is also able to control ‘Energize to Stop’ type of engines. The engine type selection is made by a jumper switch. FEATURES: • Microprocessor controlled • Manual fuel control and start • High current relay outputs • Charge alternator excitation circuit • High engine temperature protection • Low oil pressure protection • Overspeed-underspeed protection • Spare alarm input • User selectable 50/60 Hz operation • User selectable energize to start/stop operation • Standard panel dimensions (72x72mm) • Low cost TECHNICAL SPECIFICATIONS: Alternator Voltage: 15 to 300 V-AC Alternator Frequency: 50 or 60 Hz nominal. Overspeed: nominal frequency + 14% (+24% overshoot) Underspeed: 25Hz DC Supply Range: 8 to 33 V-DC. Current consumption: 80mA max. (Relay outputs open). Charge fail threshold: 6 V-DC. Charge excitation current: via 82 ohms resistor connected to the FUEL output. Stop Timeout: 30 sec. Operating temp.: -20°C (-4°F) to 70°C (158°F). Storage temp.: -30°C (-22°F) to 80°C (176°F). Maximum humidity: 95% non-condensing. Dimensions: 72x72x38mm (WxHxD) Panel cutout dimensions: 68x68 mm Weight: 140g (approx.) Installation: Front panel mounted. Retaining steel spring provided. WE DO NOT SHIP THIS PRODUCT TO USA AND CANADA
Был online: Сегодня
DATAKOM-УКРАЇНА
DATAKOM-УКРАЇНА
100% положительных отзывов