| Производитель | IFM |
|---|
| Number of inputs and outputs | Number of digital outputs: 2 |
| Process connection | threaded connection M18 x 1,5 internal thread |
| Media | Liquids; Gases | ||
| Medium temperature[°C] | -25...80 | ||
| Pressure rating |
|
| Liquids | |
|---|---|
| Medium temperature[°C] | -25...80 |
| Gases | |
|---|---|
| Medium temperature[°C] | -25...80 |
| Operating voltage[V] | 20...36 DC; (to SELV/PELV) |
| Current consumption[mA] | < 90 |
| Reverse polarity protection | yes |
| Power-on delay time[s] | 15; (optically indicated) |
| Number of inputs and outputs | Number of digital outputs: 2 |
| Total number of outputs | 2 |
| Output signal | switching signal |
| Electrical design | PNP |
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] | 2.5 |
| Permanent current rating of switching output DC[mA] | 250 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
| Liquids | |
|---|---|
| Setting range[cm/s] | 3...300 |
| Greatest sensitivity[cm/s] | 3...60 |
| Gases | |
|---|---|
| Setting range[cm/s] | 200...3000 |
| Greatest sensitivity[cm/s] | 200...800 |
| Temperature gradient[K/min] | 300 |
| Response time[s] | 1...10 |
| Liquids | |
|---|---|
| Response time[s] | 1...10 |
| Gases | |
|---|---|
| Response time[s] | 1...10 |
| Adjustment of the switch point | pushbutton |
| Ambient temperature[°C] | -25...80 |
| Protection | IP 67 |