Prom – найбільший маркетплейс України

C-SI-0300I Модуль CIB, датчик солнечного излучения, IP65

Код: TXN 143 38
Под заказ. Отправка с 20.09.2026
Цену уточняйте
Заказ у продавца — от 200 ₴

Доставка

  • Иконка доставки
    Нова Пошта

Оплата и гарантии

  • Иконка оплаты
    Оплата на счет
    IBAN UA383253650000002600101565149
  • Иконка оплаты
    Наложенный платеж
    Нова Пошта, Самовывоз
C-SI-0300I Модуль CIB, датчик солнечного излучения, IP65 - фото 1 - id-p3139833293

Характеристики и описание

Основные атрибуты

Страна производительЧехия
Производитель
Teco
СостояниеНовое

Пользовательские характеристики

DI/AI3x DI/AI
COM1x CIB slave
SENSORsolar radiation sensor
Module with 3 universal AI/DI inputs, possibility of connecting an anemometer and with integrated temperature and solar radiation sensor.
DI
DI/AI3x DI/AI
DO
AI
AO
COM1x CIB slave
SENSORsolar radiation sensor
COM - System buses
CIB - Common Installation Bus (R): Installation I/O bus1x CIB slave
DI - Organization of binary inputs
Total number of binary inputs4
Number of groups of binary inputs1
Organization of binary inputs into groups4x DI (DI/AI1 - DI/AI4)
DI - Parameters of binary inputs DC (group A)
Parameters valid for inputs on the terminals4x DI/AI1 - DI/AI4
Number of inputs in group4
Common wireGND - module ground
Combined input typeDI/AI Active, for sensing potential-free contacts and measuring resistance sensors
Galvanic isolation of inputs from internal/peripheral circuitsNo
Delay from log. 0 to log. 1200 μs
Delay from log. 1 to log. 0200 μs
Max. measuring voltage on the connected contact3,5 V DC
Internal input resistance2 kΩ
Max. resistance for closed contact, log. 1< 0,5 kΩ
Min. resistance for open contact, log. 0> 4,7 kΩ
AI - Organization of analog inputs
Total number of analog inputs5
Number of inputs per group5
Number of analog input groups1
Organization of analog inputs into groups3x DI (DI/AI1 - DI/AI3)
Input type4x DI/AI combined 1x AI current input (AI5)
Common wireGND terminal
Galvanic separation from internal circuitsNo
Diagnosticsoverload signaling in status word
Digital resolution12 bit
AI - Analog Input Ranges
Parameters valid for inputs on the terminalsDI/AI1 - DI/AI4
Voltage0-2 V
Passive sensorNTC Thermistor 12k / 25 °C (-40 to + 125 °C)
AI - Analog Input Ranges (Group A)
Parameters valid for inputs on the terminalsAI5
Ccurrent0 - 20 mA
Current4-20 mA
Power supply
Supply voltage, tolerances24/27 V DC from CIB bus
Power supply from CIB - maximum current consumption (mA)33 mA
Size and weight
Weight approx.140 g
Product dimensions (width x height x depth)65 × 100 × 40 mm
Operating conditions, product standards
Product standardČSN EN 60730-1 ed.4 :2017 (EN 60730-1:2016) -Automatic electronic control device (for household and similar purposes)
Protection class of electrical objectIII, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016)
IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989)IP65
Operating areasNormal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005)
Degree of pollution2, according to ČSN EN 60664-1 ed.2: 2008 (idt IEC 60664-1: 2007)
Overvoltage category installationIII, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007)
Type of deviceOutdoor
Working positionVertical (grommets down)
Ambient operating temperatures–25 °C až +75 °C
Operating atmospheric pressuremin. 70 kPa (<3,000 m above sea level)
Storage temperatures–25 ° C to + 85 ° C
Electromagnetic compatibility, Mechanical endurance
Electromagnetic compatibility / EmissionČSN EN 55022 ed2:2007 (mod CISPR22:2005)
Electromagnetic compatibility / Immunitymin. according to ČSN EN 60730-1 ed.2: 2001
Sinusoidal vibration endurance10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.)
Packaginng, transportation, storage
DescriptionThe module is packed in a cardboard box. The outer packaging is carried out according to the scope of the order and the method of transport in a transport container provided with labels and other information necessary for transport. Transport from the manufacturer is carried out in the manner agreed upon when ordering. Transport of the product by the customer's own means must be carried out by covered means of transport, in the position specified by the label on the packaging. The box must be stored in such a way as to prevent spontaneous movement and damage to the outer packaging. The product must not be exposed to direct weather conditions during transport and storage. The product is only allowed to be stored in clean rooms without conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20°C
Installation
Assembly descriptionThe module is mounted vertically on the support surface with the cable gland facing downwards. The assembly (basic module and possibly peripheral modules) is installed according to TXV 004 13.
Connection
Connection of power and system communicationterminal block with spring clamp 0.2-1.5 mm²
Module operation
Module configurationModule configuration The module is operated, set and diagnosed from the Mosaic development environment. Commissioning The module is operated, set and diagnosed from the MOSAIC programming environment or other parameterization software. The module is ready for operation after connecting the supply voltage and the CIB bus. The HW address is listed on the label on the module. Module diagnostics Basic diagnostics are performed internally and the result is available in the relevant registers of the Mosaic environment.
Maintenance
DescriptionThe module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected.
NoticeBecause the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!!
Warranty
GenerallyWarranty and complaint conditions are governed by the Terms and Conditions of Teco a.s.
NoticeYou must meet all the conditions of this documentation before turning on the system. The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it. Documentation subject to change.

Отзывы и вопросы

  • Отзывы (0)
  • Вопросы (0)
Еще не было отзывов об этом товаре
Был online: Сегодня
ПП Профиком
ПП Профиком
Рейтинг не сформирован

Похожее у других продавцов