The C-RQ-0600S module is the basis for several variants of modules designed for the connection of a humidity and temperature sensor, or a CO2 sensor, or an infrared motion sensor and universal analog or binary signals. Universal AI / DI inputs can be set to binary or analog with the possibility of measuring temperature sensors: support sensors PT1000, Ni1000, or a sensor with a NTC12k or KTY81-121 thermistor against a common GND wire. For another type of resistance sensor, a resistance measurement range of 0 to 160 kΩ can be selected, but the conversion to temperature and linearization must be performed in the user program. The binary signals are connected to the inputs only as a potential-free contact against the common GND conductor. The binary input can also operate in balanced input mode.
| COM - System buses |
|---|
| CIB - Common Installation Bus (R): Installation I/O bus | 1x CIB slave |
| DI - Organization of binary inputs |
|---|
| Total number of binary inputs | 4 |
| Number of groups of binary inputs | 2 |
| Organization of binary inputs into groups | 2x (DI1, DO2) 2x (DI3, DI4) |
| DI - Parameters of binary inputs DC (group A) |
|---|
| Common wire | GND - module ground |
| Combined input type | DI/AI
Active, for sensing potential-free contacts and measuring resistance sensors |
| Galvanic isolation of inputs from internal/peripheral circuits | No |
| Diagnostics | signaling of excited input in Mosaic |
| DO/RO - Organization of binary outputs |
|---|
| Total number of binary outputs | 4 |
| Number of binary output groups | 2 |
| DO - Parameters of binary transistor outputs (group A) |
|---|
| Parameters valid for the terminals | DO1 - DO4 |
| Number of transistor outputs | 4 |
| Number of output groups | 2 |
| Number of outputs in group | 2 |
| Organization of transistor outputs into groups | 2x (DO1, DO2) 2x (DO3, DO4) |
| Switching voltage | 20 V DC |
| Switching current, output load | 40 mA max. (sum of currents of all DO) |
| Short circuit protection | Yes |
| Special functions (A) | PWM |
| Operating frequency | 50 Hz max. |
| Alternation settings | 0 – 100 % |
| AI - Organization of analog inputs |
|---|
| Total number of analog inputs | 4 |
| Number of analog input groups | 2 |
| Organization of analog inputs into groups | 2x AI (AI1, AI2) 2x AI (AI3, AI4) |
| Common wire | GND terminal |
| Galvanic separation from internal circuits | No |
| Converter type | Approximation |
| Operating modes | periodic input sensing |
| Analog input error - Temperature coefficient | ± 0,1% of full scale/K |
| Analog input error - Nonlinearity | ± 0,1% of full scale |
| Analog input error - Steady state repeatability | ± 0,5% of full scale |
| AI - Analog Input Ranges (Group A) |
|---|
| Parameters valid for inputs on the terminals | AI1 - AI4 |
| Voltage | 0 to 2 V / 805.9 μV |
| Voltage input error - max. error at 25 ° C | ± 2.0% of full scale |
| Voltage input error - temperature coefficient | ± 0,05% of full scale/K |
| Voltage input error - non-linearity | ± 0.1% of full scale |
| Voltage input error - repeatability under steady state conditions | 0.5% of full scale |
| Passive sensor | NTC Thermistor 12k / 25 °C (-40 to + 125 °C) |
| DI: Voltage-free contact | 0 when> 1.5 kOhm,
1 when <0.5 kOhm |
| DI: Balanced resistance input | 2x 1k1 (tamper/0/1/tamper) |
| Resistance measurement error - maximum error at 25 ° C | ± 0.5% of full scale |
| Resistance measurement error - temperature coefficient | ± 0.05% of full scale / K |
| Resistance measurement error - non-linearity | ± 0.09% of full scale |
| Resistance measurement error - repeatability at steady conditions | 0.07% of full scale |
| Power supply |
|---|
| Nominal supply voltage (V) | 24 V DC |
| Power supply from CIB - typical current consumption (mA) | 50 mA |
| Power supply from CIB - maximum current consumption (mA) | 60 mA |
| Galvanic separation of power supply from internal circuits | No |
| Size and weight |
|---|
| Weight approx. | 50 g |
| Module width | 80 mm |
| Module height | 40 mm |
| Module depth | 15 mm |
| Product dimensions (width x height x depth) | 80 x 40 x 15 mm |
| Operating conditions, product standards |
|---|
| Product standard | ČSN EN 60730-1 ed.4 :2017 (EN 60730-1:2016) -Automatic electronic control device (for household and similar purposes) |
| Protection class of electrical object | II, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016) |
| IP rating (Ingress Protection) according to ČSN EN 60529: 1993 (idt IEC 529: 1989) | IP10 |
| Operating areas | Normal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005) |
| Degree of pollution | 2, according to ČSN EN 60664-1 ed.2: 2008 (idt IEC 60664-1: 2007) |
| Overvoltage category installation | III, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007) |
| Type of device | In the installation box, under the cover |
| Working position | Any |
| Type of operation (operating frequency) | Continuous |
| Ambient operating temperatures | -20 °C to + 55 °C |
| Operating temperature maximum (° C) | +55°C |
| Operating temperature minimum (° C) | -20°C |
| Operating relative humidity | from 10 % up to 95 % without condensation |
| Operating atmospheric pressure | min. 70 kPa (<3,000 m above sea level) |
| Storage temperatures | –25 °C to +70 °C |
| Electromagnetic compatibility, Mechanical endurance |
|---|
| Electromagnetic compatibility / Emission | A, according to EN 55032 ed. 2: 2017 (idt CISPR 32: 2015) |
| Electromagnetic compatibility / Immunity | min. according to ČSN EN 60730-1 ed.3: 2012 |
| Sinusoidal vibration endurance | 10 Hz to 57 Hz, amplitude 0,075 mm, 57 Hz to 150 Hz, acceleration 1 G (Fc test according to EN 60068-2-6: 1997 (idt IEC 68-2-6: 1995), 10 cycles per axis.) |
| Installation |
|---|
| Attention! | The modules contain components sensitive to electrostatic charge, so we observe them
principles for working with these circuits! We handle only on the module
disconnected from the power supply!
When replacing the submodules, the correctness of the deployment must be carefully checked
of the submodule cavities against the tips on the motherboard. The tubes have no coding
position and incorrect installation, may occur when the power is turned on again
damage to the submodule or even the motherboard !!! |
| Connection |
|---|
| Cross-section of connected wires fixed (min) | 0,14 mm2 |
| Cross-section of connected wires fixed (max) | 0,5 mm2 |
| Cross-section of connected wires stranded (min) | 0,14 mm2 |
| Cross-section of connected wires stranded (max) | 0,25 mm2 |
| Module operation |
|---|
| Module configuration | The module is operated, set up and diagnosed from the Mosaic development environment. |
| Module diagnostics | The basic diagnostic system of the module is a part of its standard software. It operates from module power on and operates independently of the user. Diagnostic error states of the module and connected peripheral modules of the assembly are signaled |
| Maintenance |
|---|
| Description | The module does not require any maintenance under general installation conditions. |
| Notice | Because the module contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling the removed cover. It is not allowed to directly touch the printed circuit boards without protective measures !!! |
| Warranty |
|---|
| Generally | Warranty and complaint conditions are governed by the Terms and Conditions of Teco a.s. |
| Notice | You must meet all the conditions of this documentation before turning on the system.
The system must not be put into service unless it has been verified and confirmed that the machinery meets the requirements of Directive 89/392 / EEC, in so far as it applies to it.
Documentation subject to change. |