Prom – найбільший маркетплейс України

CP-7007 CPU, 320+192 кБ, DataBox 0,5 МБ (+3 МБ), Ethernet 10/100 Мбит, USB, слот MMC/SD, 2×SCH

Код: TXN 170 07
Под заказ. Отправка с 15.08.2026
Цену уточняйте
Заказ у продавца — от 200 ₴

Доставка

  • Иконка доставки
    Подписка на доставку Smart
    Бесплатно — в отделения Новой почты
  • Иконка доставки
    Нова Пошта

Оплата и гарантии

  • Иконка оплаты
    Оплата на счет
    IBAN UA383253650000002600101565149
  • Иконка оплаты
    Наложенный платеж
    Нова Пошта, Самовывоз
CP-7007 CPU, 320+192 кБ, DataBox 0,5 МБ (+3 МБ), Ethernet 10/100 Мбит, USB, слот MMC/SD, 2×SCH - фото 1 - id-p3099378307

Характеристики и описание

Производитель
Teco
Страна производительЧехия
СостояниеНовое
CP-7007, CPU, 320kB+192kB, DataBox 0.5MB, expandable +3MB, 2x SCH, 1xUSB, 1xEthernet 10/100Mbit, MMC/SD slot
DI
DI/AI
DO
AI
AO
COM
SENSOR
COM - Serial channels
Number of internal RS-232 serial channels1
Max. baud rate (RS-232)200 kBd
Receiver input resistance (RS-232)min. 7 kOhm
Signal output level (RS-232)typ. ±8 V
Max. length of connected line (RS-232)15 m
Power supply
Supply voltage, tolerancesThe submodule is powered from the power supply the terminal device in which it is installed.
Maximum power input1,2 W
Galvanic separation of power supply from internal circuitsNo
Insulation voltage of galvanic separation1 000 VDC
Size and weight
Weight approx.50 g
Product dimensions (width x height x depth)47 × 36 × 15 mm
Operating conditions, product standards
Protection class of electrical objectIII, according to ČSN EN 61140 ed.3: 2016 (idt IEC 61140:2016)
Operating areasNormal, acc. ČSN 33 2000-1 ed.2: 2009 (mod IEC 60354-1:2005)
Degree of pollution2, according to ČSN EN 60664-1 ed.2: 2008 (idt IEC 60664-1: 2007)
Overvoltage category installationII, according to EN 60664-1 ed_2: 2008 (idt IEC 60641-1: 2007)
Type of deviceSubmodule
Type of operation (operating frequency)Continuous
Ambient operating temperatures-20 °C to + 55 °C
Operating relative humidityfrom 10 % up to 95 % without condensation
Operating atmospheric pressuremin. 70 kPa (<3,000 m above sea level)
Storage temperatures–25 °C to +70 °C
Packaginng, transportation, storage
DescriptionThe submodule is packed in a paper box according to the internal packing instructions. This documentation is also part of the package. Outer packaging is carried out according to the scope of the order and the method of transport in a transport package provided with labels and other data necessary for transport. Transport from the manufacturer is carried out in the manner agreed upon when ordering. The transport of the product by the customer's own means must be carried out by covered means of transport in the position specified by the label on the packaging. The box must be stored in such a way that it does not move spontaneously and the outer packaging is not damaged. The product must not be exposed to direct weather conditions during transport and storage. The product may only be stored in clean rooms free of conductive dust, aggressive gases and vapors. The most suitable storage temperature is 20 ° C.
Installation
Assembly descriptionThe installation of the submodule in the terminal device is always described in the documentation of the respective device. The submodule is mounted on the tips of the connector forks in the terminal device so that the 14-socket socket of the submodule is exactly opposite the 14-pin connector plug and the 11-socket socket is mounted on those connector forks that come out for insertion. into the sockets: in the case of a connector with a single-row plug, these are all its tips; See Fig. 3.1.
Exchangeable submodulesWhen connecting and / or replacing submodules, the correctness of the fitting of the submodule cavities against the fork tips of the terminal connector must be carefully checked. The sockets do not have position coding and in case of incorrect installation, the submodule and / or the terminal device may be damaged when the power supply is switched on again !!!
Connection
Serial channelsSocket strip
Module operation
Module configurationSubmodules have printed solder jumpers arranged on the printed circuit board, which can be used to modify the functions of some signals, or they can be used to connect the impedance termination of the communication line (if the submodule is at its end). Submodules are supplied with jumpers configured for the most commonly used submodule function. The figure illustrates the meaning, location and connection of individual jumpers. The configuration of some jumpers is realized already in the stage of production of a printed circuit board by a printed conductor between the faces of the jumper. This applies to jumpers labeled 'X' and 'CTS' on MR-0114 and jumpers labeled 'CTS', 'RxD', 'TEn', 'RTS' and 'REn' on MR-0124. For these jumpers, the ribbon cable must first be interrupted before changing their configuration. Then it is possible to connect the surfaces only with a drop of tin applied by soldering. The 'RTS Aut' jumper on the MR-0114 submodule is connected only by a drop of tin. The remaining jumpers are not connected.
CommissioningThe submodule is ready for operation after checking the connection of jumpers, correct insertion into the position in the terminal device and switching on the power supply of the system.
Module diagnosticsThe submodule itself is not equipped with any diagnostics. The status of the communication line (activity of transmitted data, received data and RTS signal) is usually indicated by LED diodes on the terminal device. More detailed information can be found in the documentation of the respective device.
Maintenance
DescriptionThe module does not require any maintenance under general installation conditions. The operations in which a part of the module has to be dismantled must always be carried out with the supply voltage disconnected.
WarningBecause the submodule contains semiconductor components, it is necessary to follow the principles for working with electrostatic sensitive components when handling it. It is not allowed to directly touch the printed circuit boards without protective measures !!!
Warranty
GenerallyWarranty and complaint conditions are governed by the Terms and Conditions of Teco a.s.
WarningAll conditions of this documentation must be met before switching on the device. The system must not be put into service unless it has been verified and confirmed that the environment of which the module becomes a part meets the requirements of Directive 89/392 / EEC, if applicable. Documentation subject to change.

Отзывы и вопросы

  • Отзывы (0)
  • Вопросы (0)
Еще не было отзывов об этом товаре
Был online: 03.07
ПП Профиком
ПП Профиком
Рейтинг не сформирован

Похожее у других продавцов