| Detection range |
0 ... 200 mm |
| Adjustment range |
15 ... 200 mm |
| Reference target |
standard white , 200 mm x 200 mm |
| Light source |
LED |
| Light type |
modulated visible red light |
| Polarization filter |
no |
| Diameter of the light spot |
approx. 170 mm at a distance of 200 mm |
| Optical face |
frontal |
| Ambient light limit |
EN 60947-5-2:2007+A1:2012 |
| Functional safety related parameters |
| MTTFd |
860 a |
| Mission Time (TM) |
20 a |
| Diagnostic Coverage (DC) |
0 % |
| Indicators/operating means |
| Operation indicator |
LED green: power on |
| Function indicator |
LED yellow, lights up with receiver lit |
| Control elements |
sensitivity adjustment |
| Control elements |
Light-on/dark-on changeover switch |
| Electrical specifications |
| Operating voltage |
10 ... 30 V DC |
| Ripple |
max. 10 % |
| No-load supply current |
< 20 mA |
| Output |
| Switching type |
The switching type of the sensor is adjustable. The default setting is: light-on |
| Signal output |
1 NPN output, short-circuit protected, reverse polarity protected, open collector |
| Switching voltage |
max. 30 V DC |
| Switching current |
max. 100 mA , resistive load |
| Voltage drop |
≤ 1.5 V DC |
| Switching frequency |
1000 Hz |
| Response time |
0.5 ms |