| Производитель | Pepperl Fuchs |
|---|
| Supply | ||
|---|---|---|
| Connection | terminals 11+, 12- terminals 8+, 9- |
|
| Rated voltage | 20 ... 30 V DC The maximum rated operating voltage of the devices plugged onto the Power Rail must not be exceeded. |
|
| Fusing | 5 AT/250 V AC recommended maximum utilization of the fuse: 80 % |
|
| Power dissipation | ≤ 1 W | |
| Output | ||
| Connection | Power Rail | |
| Output rated operating current | max. 4 A | |
| Output voltage | Ui ≥ rated voltage Ur = Ui - 0.6 V | |
| Fault signal | relay output: NO contact | |
| Contact loading | 30 V AC/ 2 A / cos φ ≥ 0.7 ; 40 V DC/ 2 A | |
| Energized/De-energized delay | approx. 20 ms / approx. 20 ms | |
| Indicators/settings | ||
| Display elements | LEDs | |
| Control elements | DIP-switch | |
| Configuration | via DIP switches | |
| Labeling | space for labeling at the front | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
| Conformity | ||
| Electromagnetic compatibility | NE 21:2006 | |
| Degree of protection | IEC 60529:2001 | |
| Ambient conditions | ||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions |
|